background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
1/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
Organization (S):
EDF-R & D/AMA, CS















Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
Document: V6.03.108



SSNP108 - Prestressed concrete element
in compression




Summary:

One considers an elementary structure made up of a square concrete plate crossed by a cable of
prestressed whose neutral fiber is confused with the horizontal axis of symmetry of the plate. The vertical edge
left of the plate is fixed. The cable is put in traction at its two ends in order to prestress
toggle plate. The losses of voltage along the cable are neglected.

The goal of this case-test is to validate, on a simple configuration, the method of calculation of the state of balance
of a prestressed structure of concrete. The results are validated by comparison with an analytical solution.

background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
2/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
1
Problem of reference
1.1 Geometry
The concrete plate is square; the sides have even length L = H = 2 Mr.
The thickness of the plate is worth E = 0,6 Mr.
The cable crosses the plate horizontally, with middle height, without eccentricity in the thickness. The surface of
the cross-section of the cable is worth S
has
= 1,5.10
­ 4
m
2
.
2 m
y
With
B
H = 2 m
L = 2 m
X
0
1 m


1.2
Properties of materials
Material concrete constituting the plate:
Young modulus E
B
= 3.10
10
AP
Material steel constituting the cable:
Young modulus E
has
= 2,1.10
11
AP
The Poisson's ratio is taken equal to 0 for two materials; the direction thus is privileged
of normal load application (direction
X
).
The losses of voltage being neglected, the various parameters being used for their estimate are fixed at 0.


1.3
Boundary conditions and loadings
The lower node of the left edge of the plate, i.e. the node origin (0;0), are embedded: all
DDLs of translation and rotation are locked.
The higher node of this same left edge, i.e. the node (0;2), is supported bi-
laterally: DDLs of translation locked are
DX
and
DZ
.
One applies at the two ends of the cable (which are fixed on the concrete in A and B) a normal effort of
traction: (­ F
0
;0) with node A (0;1) and (F
0
;0) with the node B (2;1), with F
0
= 2.10
5
NR.
background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
3/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
2
Reference solution
2.1 Solution
formal
Displacements in the cable and the concrete are continuous and homogeneous. Thus displacement
horizontal on the interval [0;L] is worth
U X
U
L X
L
()
=
The normal stresses in the concrete plate and the steel wire rope are written respectively
(assumption of elasticity):




+
=
+
=
=
=
0
0
L
U
E
X
U
E
L
U
E
X
U
E
L
has
has
has
L
B
B
B
where
0
0
= FS
has
is initial prestressing in the cable
and
U
L
is horizontal displacement with the X-coordinate
L
.
The balance of the unit plates and cables is written:
B B
has has
L
B
has has
S
S
U
LF
E eH E S
+
=
=
-
+
0
0
The normal effort in the cable is worth:
has
has has
L
B
B
has has
NR
E S uL F F
E eH
E eH
E S
=
+
=
+
0
0
The total effort on the vertical section of the concrete plate is worth:
B
B
L
B
B
has has
NR
E eH uL
F
E eH
E eH
E S
=
= -
+
0
One deduces from it the linear density of normal effort on the concrete plate
xx
B
B
has has
NR
F
E E
E eH
E S
= -
+
0

2.2
Numerical values of reference
The numerical values of reference are:
U
L
= ­ 1,11013974.10
­ 5
m
NR
has
= 1,99825153.10
5
NR
NR
B
= ­ 1,99825153.10
5
NR
NR
xx
= ­ 9,99125765.10
4
NR/m
background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
4/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
3 Modeling
With
3.1
Characteristics of modeling
The figure below gives a simplified representation of the mesh.
Y
X
NB002001
NC001001
NB001001
NB002002
NC001005
NB001002
The concrete plate is represented by an element
DKT
, supported by a mesh quadrangle to 4
nodes.
A thickness E = 0,6 m is affected for him, as well as a material concrete for which are defined them
behaviors
ELAS
(Young modulus E
B
= 3.10
10
AP) and
BPEL_BETON
: parameters
characteristics of this relation are fixed at 0 bus one neglects the losses of voltage along the cable of
prestressed.
The node
NB001001
is embedded:
DX
,
DY
,
DZ
,
DRX
,
DRY
and
DRZ
are locked. The node
NB002001
is
supported bilaterally:
DX
and
DZ
are locked.
The cable is represented by 4 elements
MECA_BARRE
, supported by 4 meshs segments with 2 nodes.
A surface of cross-section S
has
= 1,5.10
­ 4
m
2
their is affected, as well as a material steel for which are
defined behaviors
ELAS
(Young modulus E
has
= 2,1.10
11
AP) and
BPEL_ACIER
: parameters
characteristics of this relation are fixed at 0 (neglected losses of voltage), except for
stress ultimate elastic for which a zero value is illicit (F
prg
= 1,77.10
9
AP).
The voltage F
0
= 2.10
5
NR is applied to the nodes
NC001001
and
NC001005
. This value of voltage is
coherent with the values of section and yield stress, for a cable of prestressed of type
wiring.
The calculation of the state of balance of the unit plates and cable is carried out in only one pitch, it
behavior being elastic.
3.2
Stages of calculation and functionalities tested
The main stages of calculation correspond to the functionalities which one wishes to validate:
·
operator
DEFI_MATERIAU
: definition of the relations of behavior
BPEL_BETON
and
BPEL_ACIER
, in the particular case where losses of voltage along the cable of
prestressed are neglected (default values of the parameters);
·
operator
DEFI_CABLE_BP
: determination of a constant profile of voltage along the cable of
prestressed, losses being neglected; calculation of the coefficients of the relations kinematics
between the DDL of the nodes of the cable and the DDL of the nodes “close” to the concrete plate;
·
operator
AFFE_CHAR_MECA
: definition of a loading of the type
RELA_CINE_BP
;
·
operator
STAT_NON_LINE
, option
COMP_INCR
: calculation of the state of balance by holding account
loading of the type
RELA_CINE_BP
.
background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
5/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
4
Results of modeling A
4.1 Values
tested
4.1.1 Linear density of normal effort on the vertical section of the concrete plate
One compares the values extracted the field
SIEF_ELNO_ELGA
resulting from
STAT_NON_LINE
with the values
theoretical of reference. The extraction is done on the mesh
QD001001
representing the concrete plate.
The component to which the tests relate is
NXX
.
The tolerance of relative variation compared to the reference is worth 10
­ 6
%.
Node
Value of reference
Computed value
Relative variation
NB001001
­ 9,99125765.10
4
NR/m
­ 9,9912576495569.10
4
NR/m
­ 4,43.10
­ 11
%
NB001002
­ 9,99125765.10
4
NR/m
­ 9,9912576495569.10
4
NR/m
­ 4,43.10
­ 11
%
NB002001
­ 9,99125765.10
4
NR/m
­ 9,9912576495569.10
4
NR/m
­ 4,43.10
­ 11
%
NB002002
­ 9,99125765.10
4
NR/m
­ 9,9912576495569.10
4
NR/m
­ 4,43.10
­ 11
%

4.1.2 Horizontal displacement of the nodes of the concrete plate
One compares the values extracted the field
DEPL
resulting from
STAT_NON_LINE
with the theoretical values of
reference.
The component to which the tests relate is
DX
.
The tolerance of relative variation compared to the reference is worth 10
­ 6
%.
Node
Value of reference
Computed value
Relative variation
NB001002
­ 1,11013974.10
­ 5
m
­ 1,1101397388397.10
­ 5
m
­ 1,05.10
­ 9
%
NB002002
­ 1,11013974.10
­ 5
m
­ 1,1101397388397.10
­ 5
m
­ 1,05.10
­ 9
%

4.1.3 Normal effort in the cable
One compares the values extracted the field
SIEF_ELNO_ELGA
resulting from
STAT_NON_LINE
with the values
theoretical of reference. The extraction is done on the meshs
SG001001
for the node
NC001001
,
SG001002
for the node
NC001002
,
SG001003
for the node
NC001003
, and
SG001004
for
nodes
NC001004
and
NC001005
.
The component to which the tests relate is
NR
.
The tolerance of relative variation compared to the reference is worth 10
­ 6
%.
Node
Value of reference
Computed value
Relative variation
NC001001
1,99825153.10
5
NR
1,9982515299113.10
5
NR
­ 4,44.10
­ 11
%
NC001002
1,99825153.10
5
NR
1,9982515299113.10
5
NR
­ 4,44.10
­ 11
%
NC001003
1,99825153.10
5
NR
1,9982515299113.10
5
NR
­ 4,44.10
­ 11
%
NC001004
1,99825153.10
5
NR
1,9982515299113.10
5
NR
­ 4,44.10
­ 11
%
NC001005
1,99825153.10
5
NR
1,9982515299113.10
5
NR
­ 4,44.10
­ 11
%
background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
6/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
4.1.4 Horizontal displacement of the nodes of the cable
One compares the values extracted the field
DEPL
resulting from
STAT_NON_LINE
with the theoretical values of
reference.
The component to which the tests relate is
DX
.
The tolerance of relative variation compared to the reference is worth 10
­ 6
%.
Node
Value of reference
Computed value
Relative variation
NC001002
­ 2,77534935.10
­ 6
m
­ 2,7753493470988.10
­ 6
m
­ 1,05.10
­ 9
%
NC001003
­ 5,55069869.10
­ 6
m
­ 5,5506986941982.10
­ 6
m
7,56.10
­ 10
%
NC001004
­ 8,32604804.10
­ 6
m
­ 8,3260480412974.10
­ 6
m
1,56.10
­ 10
%
NC001005
­ 1,11013974.10
­ 5
m
­ 1,1101397388389.10
­ 5
m
­ 1,05.10
­ 9
%

4.2 Remarks
The computed values correspond indeed to those theoretically awaited. One obtains well
a compactness for the concrete plate.
One observes an infinitesimal difference between horizontal displacement with the node
NC001005
belonging to the cable and horizontal displacement to the nodes
NB001002
and
NB002002
plate
of concrete. The recorded values should be identical, but the round-off errors appearing
in the coefficients of the relations kinematics explain this infinitesimal difference.

background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
7/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
5 Modeling
B
5.1
Characteristics of modeling
For this modeling, the nodes “cables” and “concrete” are confused.
The figure below gives a simplified representation of the mesh.
Y
X
N3
N5
N1
N4
N6
N2
The concrete plate is represented by 10 elements
DKT
, supported by 10 meshs
QUAD4
.
A thickness E = 0,6 m is affected for him, as well as a material concrete for which are defined them
behaviors
ELAS
(Young modulus E
B
= 3.10
10
AP) and
BPEL_BETON
: parameters
characteristics of this relation are fixed at 0 bus one neglects the losses of voltage along the cable of
prestressed.
Nodes
N1, N5 and N3
are embedded:
DX
,
DY
,
DZ
,
DRX
,
DRY
and
DRZ
are locked.
The cable is represented by 5 elements
MECA_BARRE
, supported by 5 meshs
SEG2
.
A surface of cross-section S
has
= 1,5.10
­ 4
m
2
their is affected, as well as a material steel for which are
defined behaviors
ELAS
(Young modulus E
has
= 2,1.10
11
AP) and
BPEL_ACIER
: parameters
characteristics of this relation are fixed at 0 (neglected losses of voltage), except for
stress ultimate elastic for which a zero value is illicit (F
prg
= 1,77.10
9
AP).
The voltage F
0
= 2.10
5
NR is applied to the nodes
N5
and
N6
. This value of voltage is coherent with
values of section and yield stress, for a cable of prestressed of wiring type.
The calculation of the state of balance of the unit plates and cable is carried out in only one pitch, it
behavior being elastic.
5.2
Stages of calculation and functionalities tested
The main stages of calculation correspond to the functionalities which one wishes to validate:
·
operator
DEFI_MATERIAU
: definition of the relations of behavior
BPEL_BETON
and
BPEL_ACIER
, in the particular case where losses of voltage along the cable of
prestressed are neglected (default values of the parameters);
·
operator
DEFI_CABLE_BP
: determination of a constant profile of voltage along the cable of
prestressed, losses being neglected; calculation of the coefficients of the relations kinematics
between the DDL of the nodes of the cable and the DDL of the nodes “close” to the concrete plate;
·
operator
AFFE_CHAR_MECA
: definition of a loading of the type
RELA_CINE_BP
;
·
operator
STAT_NON_LINE
, option
COMP_INCR
: calculation of the state of balance by holding account
loading of the type
RELA_CINE_BP
.
·
operator
POST_RELEVE_T
,
NOM_CMP= `
on all the field
SIEF_ELNO_ELGA
.
background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
8/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
6
Results of modeling B
6.1 Values
tested
6.1.1 Linear density of normal effort on the vertical section of the concrete plate

Node
Value of reference
Computed value
Relative variation
N1
­ 9,99125765.10
4
NR/m
­ 9,8387753336725.10
4
NR/m
1.526%
N3
­ 9,99125765.10
4
NR/m
­ 9,8387753336725.10
4
NR/m
1.526%

6.1.2 Normal effort in the cable

Node
Value of reference
Computed value
Relative variation
N5
1,99825153.10
5
NR
1,9982248921222.10
5
NR
­ 0.001%
N6
1,99825153.10
5
NR
1,9943932520206.10
5
NR
­ 0.193%

6.1.3 Normal effort in the cable via control POST_RELEVE_T

Node
Value of reference
Computed value
N5
1,998224892.10
5
NR
1,9982248921222.10
5
NR
N6
1,994393252.10
5
NR
1,9943932520206.10
5
NR

6.2 Remarks
The computed values correspond indeed to those theoretically awaited. One obtains well
a compactness for the concrete plate.
background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
9/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A
7
Summary of the results
The results obtained are validated by comparison with an analytical solution of reference with one
very good precision.
The particular functionalities tested are as follows:
·
operator
DEFI_MATERIAU
: definition of the parameters characteristic of the materials steel
and concrete allowing the calculation of the voltage along the cable of prestressing, following the rules
BPEL;
·
operator
DEFI_CABLE_BP
: calculation of the voltage along the cable and the coefficients of
relations kinematics between the DDL of the nodes of the cable and the DDL of the “close” nodes
concrete plate;
·
operator
AFFE_CHAR_MECA
: definition of a loading of the type
RELA_CINE_BP
;
·
operator
STAT_NON_LINE
, option
COMP_INCR
: calculation of the state of balance by holding account
loading of the type
RELA_CINE_BP
.

background image
Code_Aster
®
Version
7.2
Titrate:
SSNP108 - Concrete element prestressed in compression
Date:
18/12/03
Author (S):
C. CHAVANT, X. DESROCHES, L. VIVAN
Key
:
V6.03.108-B
Page:
10/10
Manual of Validation
V6.03 booklet: Nonlinear statics of the plane systems
HT-66/03/008/A


























Intentionally white left page.